High temperature Chamber Furnace ( 1300 C-1400 C)

Ants High Temperature Laboratory Chamber Furnaces have continuous operating temperatures of 1350°C and 1400°C. These furnaces are made from low thermal mass ceramic fibre insulation and silicon carbide elements, which radiate heat directly onto the workpiece, provide rapid heating and cooling and low running costs. Recrystallized / Reaction bonded SiC elements at optimum surface loading arranged in series parallel arrangement ensure long working life and are able to withstand the stresses of intermittent operation.

The swivel type door opens outwards keeping the hot face insulation away from the operator. The furnace door entrance is made from wear resistant Alumina bricks to enhance performance. The use of double skin construction allows natural air convection to maintain a cool outer case for maximum operating safety and comfort at highest temperatures of operation.

These units are fired using specially developed power supplies to take care of varying resistance of SiC. elements with time and temperature of operation. Over temperature protection is available as optional.

 

 

Our Standard Models

Code 1350V1  
Continuous Operating Temp (C) 1350
Time to Temp (minutes)
Internal Dimension (mm) hxwxd 150x150x200
External Dimensions (mm) hxwxd
Chamber Capacity (Lt.)
Sensing Thermocouple R
Power (kW)

Code 1350V2  
Continuous Operating Temp (C) 1350
Time to Temp (minutes)
Internal Dimension (mm) hxwxd 200x200x300
External Dimensions (mm) hxwxd
Chamber Capacity (Lt.)
Sensing Thermocouple R
Power (kW)

Code 1400V2  
Continuous Operating Temp (C) 1400
Time to Temp (minutes)
Internal Dimension (mm) hxwxd 150x150x200
External Dimensions (mm) hxwxd
Chamber Capacity (Lt.)
Sensing Thermocouple R
Power (kW)

Code 1400V2  
Continuous Operating Temp (C) 1400
Time to Temp (minutes)
Internal Dimension (mm) hxwxd 200x200x300
External Dimensions (mm) hxwxd
Chamber Capacity (Lt.)
Sensing Thermocouple R
Power (kW) 7.0

  • Metal Retorts - A variety of metal retorts are available for use with this range of furnaces. This type of retort is generally used to cater for the following process conditions: a. To maintain controlled atmospheres within the heated chamber; b. To protect the heating elements and insulation from chemical attack by aggressive volatiles given off by fluxes, acids, etc.
  • Four Sided Heating - This option upgrades the standard two sided heating to four sided heating and is recommended in the following circumstances: For use with metal retorts and ceramic liners; To improve chamber temperature uniformity to meet specific process requirements; To up rate the furnace power to cope with large lo
  • R-Type Thermocouple - This option upgrades the standard K Type (mineral insulated inside Inconel sheath) thermocouple to R-Type thermocouple and is recommended if furnace is going to be used continuously at 1200 C.
  • Over Temperature - This option is recommended to protect valuable contents & for unattended operation.
  • Data Logging & Remote Controllers - A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232 and RS485.